- Number of channels in a measurement system: 64 ... 2048
- Number of channels in one measuring unit: 64/128
- One channel measurement time, msec: 1
- 128 channels sampling rate, readings/sec: 4
- ADC, bits: 16
- Main dimensionless error at operation with a single sensor, %: 0.2
- Main dimensionless error at operation with a strain bridge, %: 0.1
Software package of a system allows determination of stressed-deformed conditions of structures made of metals and composites.