Total pressure probe with a duct
Static pressure probe, ogive
Destination:
- Total and static pressure measurement in subsonic flows
- Determination of local flow speeds
- Determination of local angles of attack and sideslip angles of flat and 3D flows
| Probe type |
Minimum diameter (d), mm |
Flow speed,m sec |
Flow downwash, deg |
Length l, mm diameter (d), mm |
Systematic errors |
|
Total pressure probes, cylindrical |
| With straight edge |
0,2 |
10±300 |
±7 |
d=4±10 |
-1,0 % |
| With countersinking |
0,5 |
10±300 |
±17 |
d=6±10 |
-1,0 % |
| With a duct |
2,0 |
10±300 |
±57 ±45 |
d=8±12 |
-1,0 % |
|
Static pressure probes, cylindrical |
| With conical and ogive input section |
0,8 |
10±300 |
0 |
d=6, l=40d; l=20; l=12 |
0,5% 1,0% 4,0% |
|
Total and static pressure probes for determination of a pressure head and speed, cylindrical, axial |
| With semispherical input section |
2,6 |
10±100 10±300 |
0 |
d=8, l=12d |
ΔV=0,5V ΔV=0,3V |
|
Three-point pressure probes for determination of a value and direction of a speed of flat flows |
| Cylindrical |
2,6 |
10±180 |
α=β=±25 |
d=4±8 |
ΔV=0,1 V,Δα=0,2° |
| Semispherical |
3,0 |
10±250 |
α=β=±25 |
d=8 |
ΔV=0,2 V,Δα=0,3° |
| Spherical |
5,0 |
10±250 |
α=β=±25 |
d=6±8 |
ΔV=0,3 V,Δα=Δβ=0,3° |
| Conical |
5,0 |
10±300 |
α=β=±25 |
d=4±8 |
ΔV=0,1 V,Δα=Δβ=0,3° |